← All technologies Official India channel partner

Element Biosciences

Element Biosciences builds high-accuracy sequencing systems on avidite base chemistry (ABC): flexible and upgradable as your throughput grows.

AVITI™
Element Biosciences AVITI™ sequencer

Flexible mid-throughput sequencing

AVITI24™
Element Biosciences AVITI24™ platform

Dual-capable NGS sequencing and onboard multiomics platform

VITARI™
Element Biosciences VITARI™ benchtop sequencer

High-throughput benchtop platform, built for what comes next

Plan a run Size the run before you book it.

Enter your panels, sample count and target depth, and the AVITI™ Run Planner works out flow cell allocation, the Gb and polony budgets, and cost per sample across AVITI™, AVITI24™ and AVITI LT™.

Open the planner
On this page (9)
  1. The four platforms side by side
  2. Why we offer it
  3. Where it sits in the Genique stack
  4. What a lab needs to run it
  5. How Genique supports it in India
  6. Regulatory status in India
  7. See it in action
  8. Brochures
  9. Why source through Genique

The platforms

The AVITI™ family (AVITI LT™, AVITI™ and the multiomics-ready AVITI24™) is built on avidite base chemistry for accuracy and flexibility. As throughput grows, AVITI LT™ upgrades to AVITI™ and AVITI™ upgrades to AVITI24™.

VITARI™: shipping H2'26

A high-throughput sequencer in a compact benchtop footprint, with right-sized run configurations on two independent flow cells and run times aligned with real lab workflows.

The four platforms side by side

Output and performance for each platform, from Element Biosciences' published specifications.

Every per-run figure for AVITI™, AVITI24™ and VITARI™ assumes two flow cells running at the same time. AVITI LT™ runs one flow cell at a time, so its per-run figures are for one.

Specifications

AVITI LT™ AVITI™ AVITI24™ VITARI™
Suited to Targeted panels and smaller batches Exome, whole genome and somatic panels The same, plus cytoprofiling and multiomics High-volume whole genome sequencing
Upgrade Software update to full-throughput AVITI™ Upgrade to AVITI24™ Not applicable Not applicable
Flow cells 1 per run 2 independent, 2 lanes each 2 independent, 2 lanes each 2 independent, 6 lanes each
Output tiers Low, Medium Low, Medium, High, Cloudbreak™ UltraQ Low, Medium, High, Cloudbreak™ UltraQ High Output 2 x 150, the one flow cell announced (5 billion reads)
Read lengths 2 x 75, 2 x 150 2 x 75, 2 x 150, 2 x 300 2 x 75, 2 x 150, 2 x 300 2 x 150
Accuracy >90% Q30 >90% Q30 at 2 x 75 and 2 x 150, >85% at 2 x 300; UltraQ ≥90% Q40 and ≥70% Q50 >90% Q30 at 2 x 75 and 2 x 150, >85% at 2 x 300; UltraQ ≥90% Q40 and ≥70% Q50 >90% Q30
Output per flow cell Up to 150 Gb Up to 300 Gb Up to 450 Gb Up to 1.5 TB
Output per run Up to 150 Gb Up to 600 Gb Up to 900 Gb Up to 3 TB
Reads per run Up to 500 million Up to 2 billion Up to 3 billion Up to 10 billion
Against AVITI LT™ 1x 4x 6x 20x

The "Suited to" row is Genique's reading of the range; everything else is Element's. AVITI™ family figures are for AVITI™ OS 3.4 or later, under which AVITI24™ carries about 50% more on 2 x 75 and 2 x 150 kits. Accuracy is against Element's own libraries, so library type and preparation can move it.

Show

Output per run, by kit (Gb, two flow cells; one on AVITI LT™)

Kit AVITI LT™ AVITI™ AVITI24™ VITARI™
Low Output 2 x 75, Freestyle only 15 30 45 Not available
Low Output 2 x 150 75 150 225 Not available
Medium Output 2 x 75 75 150 225 Not available
Medium Output 2 x 150 150 300 450 Not available
Medium Output 2 x 300 Not available 120 120 Not available
High Output 2 x 75 Not available 300 450 Not available
High Output 2 x 150 Not available 600 900 3,000
High Output 2 x 300 Not available 360 360 Not available
Cloudbreak™ UltraQ High Output 2 x 150 Not available 480 480 Not available

Reads per run, by kit (millions, two flow cells; one on AVITI LT™)

Kit AVITI LT™ AVITI™ AVITI24™ VITARI™
Low Output 2 x 75, Freestyle only 100 200 300 Not available
Low Output 2 x 150 250 500 750 Not available
Medium Output 2 x 75 500 1,000 1,500 Not available
Medium Output 2 x 150 500 1,000 1,500 Not available
Medium Output 2 x 300 Not available 200 200 Not available
High Output 2 x 75 Not available 2,000 3,000 Not available
High Output 2 x 150 Not available 2,000 3,000 10,000
High Output 2 x 300 Not available 600 600 Not available
Cloudbreak™ UltraQ High Output 2 x 150 Not available 1,600 1,600 Not available

Reads are Element's target read counts, one per polony, so a read pair counts once. AVITI LT™ runs Low and Medium Output at 2 x 75 and 2 x 150; High Output and 2 x 300 need the upgrade to AVITI™. Element has announced one VITARI™ flow cell so far, High Output 2 x 150, so no other VITARI™ kit is available yet.

Samples per run

Application, data per sample AVITI LT™ AVITI™ AVITI24™ VITARI™
Whole genome, 100 Gb 1 6 8 30
Clinical exome, 12 Gb 12 50 74 250
Comprehensive solid tumour panel, DNA and RNA, 12.3 Gb 12 48 72 242

Whole samples one flow cell holds on the highest-output 2 x 150 kit, times two flow cells for AVITI™, AVITI24™ and VITARI™ and one for AVITI LT™, which is how the AVITI™ Run Planner counts them. Data per sample is the planner's own preset. Pooling, index limits and QC margins bring the real figure down; plan a run in the planner for yours.

Sources: Cloudbreak™ Sequencing User Guide, Element Biosciences MA-00058 Rev. H, for kit output and reads; Element's AVITI™ and AVITI24™ specification pages for Q30 and UltraQ; Element's published VITARI™ specification. Vendor specifications, subject to change.

Why we offer it

Q40+ accuracy, low run costs and a clear upgrade path make it a strong foundation for a modern NGS lab.

Where it sits in the Genique stack

Element Biosciences is the sequencing tier, and it is the anchor the rest of the stack is arranged around. A lab buying an AVITI™ system from Genique is buying into a chain that Genique also supplies at every other step.

  1. 01 · Sample prep

    Extraction & reagents

  2. 02 · Library prep

    Targeted panels & single-cell

  3. 03 · Sequencing

    AVITI™ · AVITI24™ · VITARI™

    • Element Biosciences
  4. 04 · Analysis

    Analysis & interpretation

  5. 05 · Report

    Interpretation & reporting

Alongside the stack: Targeted PCR & molecular diagnostics
Element Biosciences sits in the 03 Sequencing tier.

What a lab needs to run it

Site requirements for the AVITI24™ System, read off the site prep guide Element Biosciences publishes. These are manufacturer specifications rather than Genique estimates, and they are what a laboratory plans around before delivery.

  • Bench and clearance: 95.5 cm wide, 72.3 cm deep, 74.9 cm high and 155 kg, on a sturdy isolated bench, with 15 cm clear at each side and behind, 92 cm in front and 48 cm above for access to the air filter.
  • Power: 100 to 240 V at 50 or 60 Hz, which covers Indian mains directly, on a dedicated single-phase 15 A circuit with no extension cord. 600 W average and 1200 W peak. An uninterruptible supply rated at least 865 W or 1500 VA is recommended by the manufacturer.
  • Ambient: 18 to 26 °C at 30 to 70 per cent relative humidity, non-condensing, below 2000 m, with roughly 500 W of heat to carry away in normal use.
  • Kit storage: a freezer at minus 25 to minus 15 °C and a refrigerator at 2 to 8 °C, because library prep and sequencing kits ship frozen while flow cells are held chilled.
  • Data: a 2 x 151 sequencing run writes about 470 GB on AVITI™ OS 3.4 or later, and a cytoprofiling run 41 to 77 GB depending on the flow cell, so the storage connection is worth sizing before installation rather than after.
  • Delivery: Element delivers, unpacks and places the instrument, and a Genique field service engineer commissions it with a performance verification run.

How Genique supports it in India

Supplied, installed and supported by Genique in India as the official channel partner.

  • Lead time: four weeks from purchase order to delivery.
  • Service: an engineer on site, from the field team in six cities.
  • Training: on site, for as many people as the laboratory needs trained rather than a fixed number of seats. One to two days.
  • Consumables: four weeks to replenish.

Regulatory status in India

Element supplies sequencing instruments and the kits that run on them, and both are labelled by the manufacturer for research use.

  • Labelling: Research Use Only. That holds even where a product carries CE-IVD, CE-IVDR or FDA marking in another jurisdiction, because an approval granted elsewhere does not travel to India.
  • CDSCO: nothing on this page is approved or licensed by the Central Drugs Standard Control Organisation as an in-vitro diagnostic device.
  • What accreditation does and does not cover: accreditation of a laboratory evidences the quality system and the method validation under which work is performed. It does not change the regulatory status of an assay.
  • What this means for a NABL laboratory: the platform is the instrument the laboratory validates its own methods on, and the validation evidences the method rather than approving the assay.

See it in action

YouTube ↗
YouTube ↗
More videos (4)
YouTube ↗
YouTube ↗
YouTube ↗
YouTube ↗

Across the Element portfolio: AVITI24™ multiomics, Trinity™ and Avidity Sequencing chemistry, from loading to base calls. Videos courtesy of Element Biosciences.

More than a supplier. A local partner.

Local support

Field application and engineering teams across six cities in India: Gurugram, Delhi, Mumbai, Chennai, Bengaluru and Hyderabad.

Consumables continuity

Managed import, customs clearance and cold-chain logistics keep reagents flowing without interruption.

Validated onboarding

Our in-house bioinformatics team validates the platform into working pipelines, so it delivers results, not just readouts.

Interested in Element Biosciences?

Talk to our team about how it fits your needs.